  1. Turquoise -> TX(2)
    • Turquoise -> TX(2)

    • Purple -> RX(3)

    • Black -> GND(1)

    • If the equipment does not receive information from the thermograph, you can check port speed by accessing the Configuration Menu:

    • Press the blue and red button together until Enter PIN code is displayed. Press the blue button 4 times (pin code 1111). Use the red button to scroll through the options.

    • Option ENG Display > OFF must be set to ON moving the cursor with the ◄ and ► keys.

    • Continue scrolling through options until you find Baud Rate > 9600. Value must be 9600, otherwise adjust it moving with the ◄ and ► keys and adjusting with the ▲ and ▼ keys.