Key features
Cold chain
- Real-time temperature monitoring, proof of delivery, custom alerts and reporting.
- Error code detection and custom alerts to fleet managers.
- Remote temperature adjustment.
- Remote refrigeration unit start/stop.
- Remote fault clearing.
- Can connect to external door and temperature sensors.
Tachograph
- Automated remote download of vehicle and driver information.
- Automatic driver identification that matches individual drivers with specific vehicles, improving report accuracy on the MyGeotabâ„¢ platform.
- Automated downloads occur at regularly scheduled intervals, but can also be done as needed on demand (in accordance with the technical and legal requirements set by the European Union).
- Sends real-time Tachograph data, including driver name, driver status, and other useful information (in accordance with the technical and legal requirements set by the European Union).
Other expandability functionalities
The IOX-COLD allows for custom connectivity to several interfaces:
- CAN bus, RS-232, RS-485, 1-wire, TTL UART
- 4x general-purpose inputs (digital and analog)
- 2x general-purpose outputs
- USB 2.0 charging port
- Power outputs for external peripherals (supply current limit defined by the GO device)
Harness options
The IOX-COLD requires the additional harnesses for successful vehicle installation and available interface differences. For more information, refer to the Harness Identification and Application document.
Installation Scenarios
Support
For features, technical specs, and troubleshooting, see the IOX-COLD Support Document.
Troubleshooting
LED Sequence | LED State | Device Status | Action |
Slow white flashes, continuous | Initialization / boot up | Do not unplug or touch the device. Wait for device to stop initializing (LED state will change) | |
Solid green | The device is configured correctly and communicating | ||
Fast green flash occurring every 3 seconds, continuous | Low Power Mode | ||
One orange flash, continuous | CAN IOX communication issue | No connection to the GO device. Ensure the GO device is powered on and verify all connections. | |
Two orange flashes, continuous | RCU (Refrigeration control unit) communication issue | No communication with the RCU. To troubleshoot, check connections according to the installation guide. | |
Three orange flashes, continuous | Thermograph communication issue | No communication with the Thermograph. To troubleshoot, check connections according to the installation guide. | |
Four orange flashes, continuous | Tachograph communication issue | No communication with the Tachograph. To troubleshoot, check connections according to the installation guide. |
! IMPORTANT: If the problem is not resolved, repeat the installation with another IOX-COLD. If the problem persists, please contact Support.