Verify Pre Installation
- ACE Ecobiite II controllers must be PRO version 4.6 or higher, and have their GPS function activated with 15430-1 protocol.
- Earlier models, and controllers that do not yet have activation can be upgraded by contacting Ace Electronics.
- Earlier models, or those without the 15430-1 module can be upgraded by contacting Ace Electronics.
Installation
The ACE com port has +12V on pins 1 and 9, do not use a straight cable! |
---|
IOX-WRKS primary port (see above marked in green), connects to the serial port on the ACE Ecobiite II with cable HRN-FAI at 19200 baud.
Notice: Always use winter input mapping for telemetries
- AUX5- Belly Plow or Manual Spreader
- AUX6- Front Plow
- AUX7- Wing Plow
- AUX8- Tow Plow or Beacon
Configure Controller
To activate the GPS port:
- Press the red and green buttons together until “Config” is displayed (~3 seconds).
- Rotate conveyor knob until Usine/Factory is displayed. Press the green button.
- Rotate conveyor knob until “GPSACT” is displayed. Press the green button.
- Enter the 6 digit port activation code provided by ACE.
Note: Use the Spin knob to select the digit, and the green button to advance to the next character, and save. After saving the code you will be exited to the previous menu. - Move to “GPSACT” , press the green button and using the spin knob, select 154301 protocol.
- Press the green button to save this change, then press the red and green button together to exit back to main menu.
The ace controller is now configured to send data to the port and will be sending data.
In manual mode the controller only sends totals, in Auto mode it will also send rates.