Video Overview
-
-
Rexroth supplied CS550 CS660 GPS/AVL cable from control head to Primary Port required.
-
Part Number 987376776 - requires M/F null adapter.
-
Part Number 987480240 - requires M/F null adapter.
-
Part Number 987400008 - no null required
-
-
-
ACC port varies by model/hardware
-
On the Rexroth cable, use port labelled GPS or AVL to connect to the IOX-WRKS primary port.
-
Use HRN-DB9SI15 if additional length is required.
-
-
-
From the main screen of the CS660, insert the programming key into one of the USB ports of the control head.
-
Wait about 10 seconds, then press the lock symbol icon.
-
On the Configuration screen scroll down and select IoT Tracking
-
Press the Exit button door icon in the bottom left to return to the main screen.
-
Confirm setup by ensuring IoT is visible on the screen.
-
-
-
Placing the CS660 in ground speed simulation - Press and hold the speed icon for 5 seconds.
-
Adjust speed Up and Down
-
Set the material and rates on the screen to a desired setting
-
Verify data flow.
-
When test is complete, return speed to zero using the down arrow.
-
Never leave a controller in simulation mode!
-