Video Overview
-
-
HRN-CS440 required to connect the CS440 to the IOX-WRKS Primary Port. Yellow and Grey leads can be cut short (2") and taped securely to the cable.
-
If there is no Yellow and Grey leads, the cable will require a Null Adapter.
-
-
-
Connect one end of the HRN-CS440 cable to the P5 port on the CS440 controller
-
Connect the other end to the IOX-WRKS primary port.
-
Use HRN-DB9SI15 if additional length is required.
-
-
-
Insert and turn programming key (right side of unit)
-
Select SYSTEM SETUP and press enter
-
Scroll to SIMSPD+ANTI-ICING and press enter
-
Scroll to SPD SIM ONLY and press enter
-
Turn programming key to off position
-
Press ESC button
-
Press scroll up button twice to enter STATUS screen
-
Press scroll up button to increase GRND SPEED to 25-30
-
-
-
Never leave a controller in simulation mode!
-
Insert and turn programming key (right side of unit)
-
Select SYSTEM SETUP and press enter
-
Scroll to SIMSPD+ANTI-ICING and press enter
-
Next screen - scroll to NONE and press enter
-
Turn programming key to off position
-