  1. HRN-CS230 is required to connect the CS230 to the IOX-WRKS Primary Port. Controller damage possible.
    • HRN-CS230 is required to connect the CS230 to the IOX-WRKS Primary Port.

    • Controller damage possible.

    • CS230 data cable is ignition powered ONLY if unit is non-AC model.

    • CS-230 = Requires cable to be ignition powered.

    • CS-230-AC = DO NOT power cable

  2. Connect one end of the HRN-CS230 cable to the COMM port on the CS230 controller Connect the other end to the IOX-WRKS primary port.
    • Connect one end of the HRN-CS230 cable to the COMM port on the CS230 controller

    • Connect the other end to the IOX-WRKS primary port.

    • Use HRN-DB9SI15 if additional length is required.

    • Ensure the IOX-WRKS has the correct controller configuration loaded before proceeding to verification / simulation mode.

  3. Turn the CS230 on and set the Application and spread rates using the labelled knobs on the controller. The display could be showing a number of parameters depending on it’s programming. Use the Increment buttons to toggle through the settings.
    • Turn the CS230 on and set the Application and spread rates using the labelled knobs on the controller.

    • The display could be showing a number of parameters depending on it’s programming. Use the Increment buttons to toggle through the settings.

    • “ARS” is Application Rate Setting (Usually in Lbs/mile), “AR” is actual rate which should be zero due to the vehicle not moving.

    • Controller data should be captured when the unit is on, there are no errors displayed, and it is in operation mode with rates set.

    • With the programming key and always starting with dials at zero before entering the programming mode, you can check the following:

    • Set the rate and application dials to access the parameter of interest. For example spread 9, and application 9 accesses Parameter 99.

    • Parameter 99 displays the Software Version.

    • Parameter 62 the GPS data format, which should be set at zero

    • Using the increment and blast buttons will allow a change and save of the new value.

    • Please do not change any settings without first confirming with the customer !

  4. Ground speed simulation is not necessary, and can only be activated using the CS simulator module
    • Ground speed simulation is not necessary, and can only be activated using the CS simulator module