Skip to main content

v1.0

Major VersionM

by Jason Fox

Video Overview

  1. Muncie to IOX-WRKS CANBUS requires HRN-DS02S8
    • Muncie to IOX-WRKS CANBUS requires HRN-DS02S8

  2. Connect HRN-DS02S8 to the AVL CAN port on cable coming from controller. Connect the other to the IOX-WRKS CANBUS connection Connect the other to the IOX-WRKS CANBUS connection
    • Connect HRN-DS02S8 to the AVL CAN port on cable coming from controller.

    • Connect the other to the IOX-WRKS CANBUS connection

  3. Once cables are secured be sure to power cycle the controller to reset COM.
    • Once cables are secured be sure to power cycle the controller to reset COM.

    • To setup Data Logging:

    • Use the Auger and Spinner knobs (push to change) to scroll through the screens.

    • Enter “6795" at the configuration passcode to confirm and set COM.

    • On the Datalog screen:

    • Set Timer Interval to “10 sec”

    • Set Log Clear to “AUTO”

    • Ensure the IOX-WRKS has the correct controller configuration loaded before proceeding to verification / simulation mode.

    • At Configuration passcode enter “SENSOR”

    • Set SIM speed (~30) and close window.

    • Confirm SIM Speed on Totals page.

    • Start spreader and conform rates changing (Totals)

    • Always reset SIM speed to zero on completion of tests!!

    • Never leave a controller in simulation mode!

Finish Line

Jason Fox

Member since: 09/14/2023

27 Guides authored

Team

Field Service Specialists Member of Field Service Specialists

8 Members

68 Guides authored