  1. Hwasung Thermo units requires the HRN-CCHW harness.
    • Hwasung Thermo units requires the HRN-CCHW harness.

  2. The firmware version of the display must be 3.89 or newer. Older versions are not supported. There are two ways of checking the in-cabin controller firmware version:
    • The firmware version of the display must be 3.89 or newer. Older versions are not supported.

    • There are two ways of checking the in-cabin controller firmware version:

    • Sometimes, the firmware version can be available on stickers placed on the in-cabin controller. The following examples outline two controllers which contain the versions “3.89” and “5.11”. The firmware version is printed on the display:

  3. Alternatively, you can check the firmware on the controller itself by doing the following: Press the power button to turn the controller on. Hold the UP button for 3 seconds.
    • Alternatively, you can check the firmware on the controller itself by doing the following:

    • Press the power button to turn the controller on.

    • Hold the UP button for 3 seconds.

    • The firmware version, outlined in red, is displayed on the screen.

    • In this example, the firmware version is 5.16

  4. Not all 3.89 or newer firmware versions need to be configured. If the in-cabin controller you are connected to does not have the following parameters, do not proceed with the following steps.
    • Not all 3.89 or newer firmware versions need to be configured. If the in-cabin controller you are connected to does not have the following parameters, do not proceed with the following steps.

    • To ensure the refrigeration unit will communicate with the the IOX-COLD, configure the in-cabin controller to the outlined settings.

    • Press and hold the UP button for 6 seconds, then using the UP and DOWN buttons to enter 5108 as the password to access the engineering menu.

    • Use the DEF button to move left, En-D button to move right, and MODE button to accept.

    • Use the UP and DOWN button to move between the available settings, then modify a configuration by pressing MODE. The value flashes to indicate that you are modifying the setting.

    • Use the UP and DOWN button to modify the value, then press MODE to save the setting.

    • The menu closes automatically if no button is pressed for 2 seconds.

    • Configure the following: Change the configured communication protocol from PF-A to PF-r. Change the HPuS parameter to HPon value.

  5. Locate the controller in the vehicle cabin. Connect the 4-Pin connector of the HRN-CCHW harness to the port located on the bottom of the controller.
    • Locate the controller in the vehicle cabin.

    • Connect the 4-Pin connector of the HRN-CCHW harness to the port located on the bottom of the controller.

    • Ensure the connection is secure and locked into place.

  6. The HRN-CCHW contains loose wires which allow connecting the IOX-COLD to additional sensors such as 1-Wire temperature sensors or door sensors.
    • The HRN-CCHW contains loose wires which allow connecting the IOX-COLD to additional sensors such as 1-Wire temperature sensors or door sensors.

    • Refer to the Accessories category for installation instructions.