Video Overview
-
-
The IOX-WRKS primary port connects to the DB9 (RS-232) serial port on the control module of the Force America 6100 with the HRN-FAI cable.
-
-
-
Power on the Force America 6100 controller.
-
Enter the [Calibration] menu.
-
An access code may be required and can be obtained from your Force America representative.
-
Under the [Configuration > Enabled Options] menu set [SIM Speed] to "Enabled".
-
Set [Event Logging (Serial] to "AVL".
-
Navigate to the [Configuration > Event Logging > Intervals] menu and set each parameter to "Enabled".
-
Navigate to the [Calibration > System Management > Shutdown] menu and select “Restart Now” to reboot the controller.
-
The Force America 6100 controller is now configured to stream data to the IOX-WRKS.
-
-
-
From the operator screen, set [SIM Speed] to "~25 MPH / KPH".
-
Press the green knob (on and off) on the controller to trigger an event change.
-
Verify the data.
-
Ensure the [SIM Speed] is returned to "Disabled" if you enabled this feature.
-