  1. If the Force America 5100EX is installed with the joystick control, then the Force America part number 1104107 - COM Port “Y” cable is required to allow dual COM connections for both the joystick control and IOX-WRKS.
    • If the Force America 5100EX is installed with the joystick control, then the Force America part number 1104107 - COM Port “Y” cable is required to allow dual COM connections for both the joystick control and IOX-WRKS.

    • The Force America part number 1104107 - COM Port “Y” cable is available from Force America.

  2. The IOX-WRKS primary port "must" connect to the serial port on the back of the Force America 5100EX with the HRN-FAI cable. Interference with the controller will occur if an improper cable is used. The IOX-WRKS primary port "must" connect to the serial port on the back of the Force America 5100EX with the HRN-FAI cable. Interference with the controller will occur if an improper cable is used. The IOX-WRKS primary port "must" connect to the serial port on the back of the Force America 5100EX with the HRN-FAI cable. Interference with the controller will occur if an improper cable is used.
    • The IOX-WRKS primary port "must" connect to the serial port on the back of the Force America 5100EX with the HRN-FAI cable. Interference with the controller will occur if an improper cable is used.

  3. Connect the IOX-WRKS primary port to the serial port on the Force America 5100EX using the HRN-FAI cable.
    • Connect the IOX-WRKS primary port to the serial port on the Force America 5100EX using the HRN-FAI cable.

    • Power on the Force America 5100EX controller.

    • Enter the [Calibration] menu.

    • An access code may be required and can be obtained from your Force America representative.

    • Under the [Calibration > Config] menu, set [Event Logging] to "AVL".

    • Press "Ok" to save the setting and exit the calibration menu.

    • The Force America 5100EX controller is now configured to stream data to the IOX-WRKS.

    • Ensure the IOX-WRKS has the correct controller configuration loaded before proceeding to verification / simulation mode.

    • Set [Spinner], [Conveyor] and [Liquid] to desired settings.

    • Press the green knob (on and off) on the controller to trigger an event change.

    • Verify the data.

    • A computer can be used to confirm data is flowing from the serial port on the Force America 5100EX controller.

    • Connect your computer's COM port using a using the HRN-FAI cable to the serial port on the Force America 5100EX controller.

    • Open up a Terminal application, select the correct COM port on your computer and set the baud rate to "9600".

    • Press the green knob (on and off) on the controller to trigger an event change.

    • Each time the controller sends data you will be able to see it in the Terminal application.