Skip to main content

v1.10

Minor Versionm

by Alkesh Dhak

    • Confirm that the Certified Power / Cirus XDS firmware on the main power-up screen is 4.02 or greater.

    • Prior to installation, contact your Certified Power representative for instructions on how to enter the menu system as an administrator.

  1. The IOX-WRKS primary port connects to the PC port on the Certified Power / Cirus XDS using the standard null cable HRN-DB9NM. The IOX-WRKS primary port connects to the PC port on the Certified Power / Cirus XDS using the standard null cable HRN-DB9NM.
    • The IOX-WRKS primary port connects to the PC port on the Certified Power / Cirus XDS using the standard null cable HRN-DB9NM.

  2. Confirm that the data format is “String 1".
    • Confirm that the data format is “String 1".

    • Select [System Setup].

    • Select [Telematics].

    • Set to "String 1" and save settings.

    • Reboot the controller.

    • The data will now be correctly formatted and the baud rate will be set to "9600".

    • Set the controller to 10 second reporting intervals.

    • Login to the controller as "admin" (password is “admin”).

    • Select [Setup].

    • Select [Telematics].

    • Use the drop down menu to change [Breadcrumb Rates] to "10".

    • Save the settings and exit the menu.

    • Ensure the IOX-WRKS has the correct controller configuration loaded before proceeding to verification / simulation mode.

  3. Using the Console and the LCD screen, follow the instructions below to place the Certified Power / Cirus XDS into Simulation Mode for verification.
    • Using the Console and the LCD screen, follow the instructions below to place the Certified Power / Cirus XDS into Simulation Mode for verification.

    • Place the controller in “Manual” mode. This will simulate ground speed and allow for data capture and verification. Return the controller to "Auto" mode after verification is complete.

    • If "Manual" mode is unavailable on the operator screen, follow the instructions below.

    • Press and hold the MODE button on the operator panel, or touch the side bar on the screen.

    • Select [Technician] and enter the password (default is blank). Press "Okay".

    • Set the [Test Speed] to "30MPH" and make sure you are in "Auto Pause".

    • Set the [Material Rate] on screen to "200lbs/mi". Press "Pause".

    • Perform data capture and verification.

    • Place the controller back into its original settings after verification is complete.

Finish Line

Alkesh Dhak

Member since: 04/07/2022

39 Guides authored

Team