ACE Ecobiite II controllers must be PRO version 4.6 or higher, and have their GPS function activated with 15430-1 protocol.
-
Controllers may be shipped factory activated, or may require a code from ACE to activate AVL functionality.
-
The HRN-FAI cable must be used to prevent equipment damage. The ACE com port has +12V on pins 1 and 9. Do not use a standard straight cable!
-
-
-
The IOX-WRKS primary port connects (19200 baud) to the serial port on the ACE Ecobiite II+ with the HRN-FAI cable.
-
Enter the access code to access the configuration setup area.
-
Select Ecobite calibration
-
Rotate conveyor knob until Usine/Factory is displayed. Press the green button.
-
Rotate conveyor knob until GPSACT. Press the green button.
-
Enter the 6 digit port activation code provided by ACE. (This code may be factory entered)
-
Use the Spin knob to select the digit, and the green button to advance to the next character, and save.
-
After saving the code you will be exited to the previous menu.
-
-
-
Move to GPSPTC, press the green button and using the spin knob, select 154301 protocol.
-
Press the green button to save this change, then press the red and green button together to exit back to main menu.
-
The ace controller is now configured to send data to the port and will be sending data.
-
In manual mode the controller only sends totals. In auto mode it will also send rates.
-
Ensure the IOX-WRKS has the correct controller configuration loaded before proceeding to verification / simulation mode.
-